Our products are ideal for these applications:

ParameterApplication
Product identificationProduct identification

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
RAMSProduct identification1 Parameter8 Parameter

Our products are ideal for these applications:

ParameterApplication
Dust in flue gas (dust emission)Dust in exhaust gas after dust collectors

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
StackGuardDust in flue gas (dust emission)0 .. 0.05 PLA0 .. 100 PLA
StackGuard systemDust in flue gas (dust emission)0 .. 0.05 PLA0 .. 1'000 PLA

Our products are ideal for these applications:

ParameterApplication
Color ExtinctionColor in the plant outlet
Color HazenColor in the plant outlet
Oil (free-fall flow cell)Oil traces in the plant outlet
Oil discharge monitoringOil discharge monitoring
Turbidity in dirty waterTurbidity in the plant outlet (industrial wastewater)

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in dirty water0 .. 10 FNU0 .. 4'000 FNU
AquaScat WTMTurbidity in dirty water0 .. 0.1 FNU0 .. 4'000 FNU
ColorPlus bypassColor Hazen0 .. 100 .. 300
Color Extinction0 .. 1 E/m0 .. 60 E/m
ColorPlus Ex bypassColor Hazen0 .. 100 .. 20'000
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
ColorPlus Ex in-lineColor Hazen0 .. 100 .. 20'000
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
ColorPlus in-lineColor Hazen0 .. 100 .. 20'000
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
OilGuardOil (free-fall flow cell)0 .. 0.3 FLU0 .. 100 FLU
OilGuard ExOil (free-fall flow cell)0 .. 0.3 FLU0 .. 100 FLU
OilGuard Ex MOil discharge monitoring0 .. 100 ppm0 .. 100 ppm
RAMSColor Extinction0 .. 100 %0 .. 100 %

Our products are ideal for these applications:

ParameterApplication
Turbidity in clean waterFiltration monitoring

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in clean water0 .. 10 FNU0 .. 4'000 FNU
AquaScat PTurbidity in clean water0.1 FNU100 FNU
AquaScat WTMTurbidity in clean water0 .. 0.1 FNU0 .. 500 FNU

Our products are ideal for these applications:

ParameterApplication
Turbidity in brewery laboratoryTurbidity measurement in laboratory
Turbidity in distilery/winery laboratoryTurbidity in laboratories

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
LabScatTurbidity in brewery laboratory-0 .. 100 (500) EBC
Turbidity in distilery/winery laboratory-0 .. 400 (2000) NTU

Our products are ideal for these applications:

ParameterApplication
Oil mistOil mist in Diesel engine rooms

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
VisGuard OMDOil mist0 .. 0.1 PLA0 .. 100 PLA

Our products are ideal for these applications:

ParameterApplication
Chlorine dioxide in liquidsChlorine dioxide in bleaching solutions
Chrome 3Heavy metals in treating bath solutions
Chrome 6Heavy metals in treating bath solutions
Color EBCColoring
Color ExtinctionColoring
Color HazenColoring
Color SayboltColoring
CopperHeavy metals in treating bath solutions
NickelHeavy metals in treating bath solutions
Phase separationPhase separation on product change
Turbidity in beveragesTurbidity after filtration
Turbidity in clean waterTurbidity in process water
Turbidity in processTurbidity after filtration

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in clean water0 .. 10 FNU0 .. 4'000 FNU
AquaScat PTurbidity in clean water0.1 FNU100 FNU
AquaScat WTMTurbidity in clean water0 .. 0.1 FNU0 .. 500 FNU
ColorPlus bypassColor Hazen0 .. 100 .. 300
Color Extinction0 .. 1 E/m0 .. 60 E/m
ColorPlus Ex bypassChlorine dioxide in liquids0 .. 5.5 mg/l ClO2
0 .. 14.45 mg/l act Cl2
0 .. 16.44 g/l ClO2
0 .. 43.35 g/l act Cl2
Chrome 30 .. 1.5 mg/l0 .. 40 g/l
Chrome 60 .. 0.5 mg/l0 .. 1.25 g/l
Copper0 .. 0.2 g/l0 .. 600 g/l
Nickel0 .. 0.125 g/l0 .. 375 g/l
Color EBC0 .. 0.250 .. 750
Color Hazen0 .. 100 .. 20'000
Color Saybolt+30 .. +25+30 .. -20
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
ColorPlus Ex in-lineChlorine dioxide in liquids0 .. 5.5 mg/l ClO2
0 .. 14.45 mg/l act Cl2
0 .. 16.44 g/l ClO2
0 .. 43.35 g/l act Cl2
Chrome 30 .. 1.5 mg/l0 .. 40 g/l
Chrome 60 .. 0.5 mg/l0 .. 1.25 g/l
Copper0 .. 0.2 g/l0 .. 600 g/l
Nickel0 .. 0.125 g/l0 .. 375 g/l
Color EBC0 .. 0.250 .. 750
Color Hazen0 .. 100 .. 20'000
Color Saybolt+30 .. +25+30 .. -20
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
ColorPlus in-lineChlorine dioxide in liquids0 .. 5.5 mg/l ClO2
0 .. 14.45 mg/l act Cl2
0 .. 16.44 g/l ClO2
0 .. 43.35 g/l act Cl2
Chrome 30 .. 1.5 mg/l0 .. 40 g/l
Chrome 60 .. 0.5 mg/l0 .. 1.25 g/l
Copper0 .. 0.2 g/l0 .. 600 g/l
Nickel0 .. 0.125 g/l0 .. 375 g/l
Color EBC0 .. 0.250 .. 750
Color Hazen0 .. 100 .. 20'000
Color Saybolt+30 .. +25+30 .. -20
Color Extinction0 .. 1 E/m0 .. 3'000 E/m
DualScatTurbidity in beverages0 .. 0.5 EBC0 .. 500 EBC
Turbidity in process0 .. 0.5 EBC0 .. 500 EBC
DualScat ExTurbidity in beverages0 .. 0.5 EBC0 .. 500 EBC
Turbidity in process0 .. 2 NTU0 .. 2'000 NTU
RAMSTurbidity in beverages0 .. 100 %0 .. 100 %
Turbidity in process0 .. 100 %0 .. 100 %
Color Extinction0 .. 100 %0 .. 100 %
Phase separation0 .. 100 %0 .. 100 %

Our products are ideal for these applications:

ParameterApplication
VisibilityVisibility measurement

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
FireGuardVisibility0 .. 100 mE/m0 .. 3 E/m
VisGuard ExtractiveVisibility0 .. 4 mE/m0 .. 2 E/m
VisGuard In-situVisibility0 .. 4 mE/m0 .. 2 E/m

Our products are ideal for these applications:

ParameterApplication
Oil (closed flow cell)Oil traces in the condensate return
Turbidity in clean waterTurbidity in feeder water
Turbidity in processTurbidity in the water/steam circuit

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in clean water0 .. 10 FNU0 .. 4'000 FNU
AquaScat PTurbidity in clean water0.1 FNU100 FNU
AquaScat WTMTurbidity in clean water0 .. 0.1 FNU0 .. 500 FNU
DualScatTurbidity in process0 .. 0.5 EBC0 .. 500 EBC
DualScat ExTurbidity in process0 .. 2 NTU0 .. 2'000 NTU
OilGuardOil (closed flow cell)0 .. 0.3 FLU0 .. 30 FLU
OilGuard ExOil (closed flow cell)0 .. 0.3 FLU0 .. 30 FLU
RAMSTurbidity in process0 .. 100 %0 .. 100 %

Our products are ideal for these applications:

ParameterApplication
Color HazenColor in filtered liquids
Oil (free-fall flow cell)Oil traces in raw water
Ozone in airOzone in air after generator
Turbidity in clean waterTurbidity after filtration and final control
Turbidity in water
Turbidity in dirty waterTurbidity in raw water (surface, ground, spring water), after flocculation and filtration

The following products are used successfully:

ProductParameterLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in clean water0 .. 10 FNU0 .. 4'000 FNU
Turbidity in dirty water0 .. 10 FNU0 .. 4'000 FNU
AquaScat PTurbidity in clean water0.1 FNU100 FNU
AquaScat WTMTurbidity in clean water0 .. 0.1 FNU0 .. 500 FNU
Turbidity in dirty water0 .. 0.1 FNU0 .. 4'000 FNU
ColorPlus bypassColor Hazen0 .. 100 .. 300
ColorPlus Ex bypassOzone in air0 .. 0.17 g/m30 .. 511 g/m3
Color Hazen0 .. 100 .. 20'000
ColorPlus Ex in-lineOzone in air0 .. 0.17 g/m30 .. 511 g/m3
Color Hazen0 .. 100 .. 20'000
ColorPlus in-lineOzone in air0 .. 0.17 g/m30 .. 511 g/m3
Color Hazen0 .. 100 .. 20'000
ColorPlus O3 GasOzone in air0 .. 50 mg/m30 .. 300 g/m3
OilGuardOil (free-fall flow cell)0 .. 0.3 FLU0 .. 100 FLU
OilGuard ExOil (free-fall flow cell)0 .. 0.3 FLU0 .. 100 FLU