These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
AquaScat WTMTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
ColorPlus bypassConcentration of Phenol in Waste Water0-0.05 E0-3 E
ColorPlus Ex in-lineConcentration of PNP (Poly-Nitrophenol) in Waste Water0-0.05 E0-3 E
DualScat ExTurbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
OilGuardOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
PhaseGuardLeckage of glycol from cooling circuit0-100%
TurBiScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU

Our products are used successfully for these applications:

Measuring task
Dust Concentration in Air
Early Fire / Smoke Detection in Railway Tunnel
Visibility in Railway Tunnel

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
FireGuardEarly Fire / Smoke Detection in Railway Tunnel0-0.05 PLA0-100 PLA
VisGuard ExtractiveDust Concentration in Air0-0.05 PLA0-100 PLA
Visibility in Railway Tunnel0-0.05 PLA0-100 PLA
VisGuard In-situDust Concentration in Air0-0.05 PLA0-100 PLA
Visibility in Railway Tunnel0-0.05 PLA0-100 PLA

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus bypassApplication undisclosed
ColorPlus Ex in-lineApplication undisclosed
Color (EBC) at the blending unit0-5 EBC F0-208 EBC F
ColorPlus in-lineApplication undisclosed
Color (EBC) at the blending unit0-5 EBC F0-208 EBC F
Color (EBC) of Beer0-5 EBC F0-208 EBC F
LabScatTurbidity in the Brewery Laboratory0-0.5 EBC0-500 EBC
PhaseGuardUnknown measuring task
Application undisclosed
Phase Separation Beer / Water0-100 %
Phase Separation Yeast / Beer0-100 %
Turbidity After Lauter Tun (Wort)0-1 EBC0-1000 EBC
Turbidity at Whirlpool / Centrifuge / Separator0-1 EBC0-1000 EBC
TurbiGuardUnknown measuring task
Turbidity After Lauter Tun (Wort)0-1 EBC0-1000 EBC
Turbidity at Whirlpool / Centrifuge / Separator0-1 EBC0-1000 EBC
Turbidity For KG Dosing0-1 EBC0-1000 EBC
TurBiScatTurbidity After Lauter Tun (Wort)0-1 EBC0-1000 EBC
Turbidity After Plate Filter0-1 EBC0-1000 EBC
Turbidity After PVPP Filtration0-1 EBC0-1000 EBC
Turbidity at Whirlpool / Centrifuge / Separator0-1 EBC0-1000 EBC
Turbidity Before Filling0-1 EBC0-1000 EBC
Turbidity For Beer Filtration Monitoring0-1 EBC0-1000 EBC
Turbidity For KG Dosing0-1 EBC0-1000 EBC
Turbidity For PVPP Dosing0-1 EBC0-1000 EBC
VisGuard In-situApplication undisclosed

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
ColorPlus bypassApplication undisclosed
Color (Hazen) in Process / Waste Water0-0.05 E0-3 E
Concentration of Aniline in Condensate0-0.05 E0-3 E
Concentration of Clorine in Hydrogen0-0.05 E0-3 E
Concentration of Ironpentacarbonyl0-0.05 E0-3 E
Ozone in Air or O20-0.1 g/Nm30-300 g/Nm3
Ozone in Ultra Pure Water0-1 mg/l0-200 mg/l
ColorPlus Ex bypassUnknown measuring task
ColorPlus Ex in-lineApplication undisclosed
Color (Hazen) in Organic Based Oils0-0.05 E0-3 E
Color (Hazen) of Acrylic Acid0-0.05 E0-3 E
Color (Hazen) of Metacrylic Acid0-0.05 E0-3 E
Color (Hazen) of Phthalic Acid Anhydride0-0.05 E0-3 E
Concentration of PNP (Poly-Nitrophenol) in Waste Water0-0.05 E0-3 E
ColorPlus in-lineUnknown measuring task
Application undisclosed
Concentration of Chlorine in NOCl0-0.05 E0-3 E
Concentration of Copper in H2SO40-0.05 E0-3 E
Ozone in Ultra Pure Water0-1 mg/l0-200 mg/l
ColorPlus O3 GasOzone in Air or O20-0.1 g/Nm30-300 g/Nm3
ColorPlus O3 WaterOzone in Ultra Pure Water0-1 mg/l0-200 mg/l
DualScat ExTurbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Silicone Oil0-10 ppm SiO20-1000 ppm SiO2
Turbidity in the Chemical- / Pharmaceutical Laboratory0-2 NTU0-2000 NTU
OilGuardOil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Cooling Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Raw Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
PhaseGuardUnknown measuring task
Application undisclosed
TurBiScatUnknown measuring task
Turbidity For Insuline Filtration0-4 NTU0-4000 NTU
Turbidity in Liquified Gas0-2 NTU0-2000 NTU
Turbidity in Methacrylic Acid0-2 NTU0-2000 NTU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
VisGuard In-situUnknown measuring task
Application undisclosed

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat PTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
Turbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
ColorPlus Ex bypassUnknown measuring task
ColorPlus Ex in-lineColor (EBC) at the blending unit0-5 EBC F0-208 EBC F
ColorPlus in-lineColor (EBC) at the blending unit0-5 EBC F0-208 EBC F
DualScat ExTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
LabScatTurbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
TurBiScatTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
ColorPlus bypassColor (Hazen) in Process / Waste Water0-0.05 E0-3 E
OilGuardUnknown measuring task
Oil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Cooling Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Raw Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
StackGuardContinuous Stack Emission Monitoring (CSEM)0-0.05 PLA0-100 PLA
StackGuard systemContinuous Stack Emission Monitoring (CSEM)0-0.05 PLA0-100 PLA
TurBiScatTurbidity in Raw Water0-0.01 FNU0-4000 FNU

Our products are used successfully for these applications:

Measuring task
Dust Concentration in Air
Turbidity in Scrubber Water

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat WTMTurbidity in Scrubber Water0-0.1 NTU0-4000 NTU
VisGuard ExtractiveDust Concentration in Air0-0.05 PLA0-100 PLA
VisGuard In-situDust Concentration in Air0-0.05 PLA0-100 PLA

Our products are used successfully for these applications:

Measuring task
Concentration of Copper in H2SO4

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus in-lineConcentration of Copper in H2SO40-0.05 E0-3 E

Our products are used successfully for these applications:

Measuring task
Turbidity in Instant Tea

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
TurBiScatTurbidity in Instant Tea0-4 NTU0-4000 NTU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus Ex in-lineTMQH / Toluol420700
ColorPlus in-lineConcentration of Coffee in Condensate0- 0.05 E 0-3 E
Concentration of Flavonoids in Lemon Juice0-900 ppm
DualScat ExTurbidity in Herbal Medicines0-2 NTU0-2000 NTU
LabScatConcentration of Wax in Sunflower Oil0-2 NTU0-2000 NTU
Turbidity in colours dies for the food industry0-800 NTU
TurBiScatTurbidity For Soya Sauce Filtration Monitoring0-4 NTU0-4000 NTU
Turbidity in Fruit Juice0-4 NTU0-4000 NTU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
AquaScat WTMTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
DualScat ExTurbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
OilGuardOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
TurBiScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU

Our products are used successfully for these applications:

Measuring task
Milk Fat Concentration

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
TurbiGuardMilk Fat Concentration0-5%0-5%

Our products are used successfully for these applications:

Measuring task
Oil Mist Detection

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
TurBiScatOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard ExtractiveOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard In-situOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard OMDOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA

Our products are used successfully for these applications:

Measuring task
Continuous Stack Emission Monitoring (CSEM)
Dust Concentration in Air

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
StackGuardContinuous Stack Emission Monitoring (CSEM)0-0.05 PLA0-100 PLA
StackGuard systemContinuous Stack Emission Monitoring (CSEM)0-0.05 PLA0-100 PLA
VisGuard ExtractiveDust Concentration in Air0-0.05 PLA0-100 PLA
VisGuard In-situDust Concentration in Air0-0.05 PLA0-100 PLA

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
OilGuard ExODME For Bilge Water Overboard Discharge0-100 ppm Oil
ODME For Slop Tank Overboard Discharge0-100 ppm Oil
OilGuard Ex MUnknown measuring task
ODME For Bilge Water Overboard Discharge0-100 ppm Oil
ODME For Slop Tank Overboard Discharge0-100 ppm Oil
TurBiScatODME For Ballast Water Overboard Discharge0-100 ppm Oil
Oil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard ExtractiveOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard In-situOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA
VisGuard OMDOil Mist Detection0-0.05 mg/m3 PLA0-100 mg/m3 PLA

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
ColorPlus bypassColor (Hazen) in Process / Waste Water0-0.05 E0-3 E
ColorPlus Ex in-lineColor (Hazen) of Acrylic Acid0-0.05 E0-3 E
Color (Hazen) of Maleic Acid Anhydride0-0.05 E0-3 E
Color (Hazen) of Phthalic Acid Anhydride0-0.05 E0-3 E
ColorPlus in-lineColor (Hazen) of Maleic Acid Anhydride0-0.05 E0-3 E
DualScat ExUnknown measuring task
Turbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
Turbidity to measure water and solids concentration in kerosene0-100 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
OilGuardOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Cooling Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Raw Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
TurBiScatTurbidity in Liquified Gas0-2 NTU0-2000 NTU
Turbidity in Methacrylic Acid0-2 NTU0-2000 NTU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus bypassApplication undisclosed
Ozone in Ultra Pure Water0-1 mg/l0-200 mg/l
ColorPlus Ex in-lineApplication undisclosed
ColorPlus in-lineApplication undisclosed
Ozone in Ultra Pure Water0-1 mg/l0-200 mg/l
ColorPlus O3 WaterOzone in Ultra Pure Water0-1 mg/l0-200 mg/l
LabScatTurbidity in the Chemical- / Pharmaceutical Laboratory0-2 NTU0-2000 NTU
PhaseGuardApplication undisclosed
TurBiScatTurbidity after filtration of isotonic sodium chloride0-4 NTU0-4000 NTU
VisGuard In-situApplication undisclosed

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMTurbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Scrubber Water0-0.1 NTU0-4000 NTU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
ColorPlus bypassColor (Hazen) in Process / Waste Water0-0.05 E0-3 E
Concentration of Phenol in Waste Water0-0.05 E0-3 E
ColorPlus Ex in-lineColor (ASTM) of Diesel / Gasoline0-1 ASTM0-5 ASTM
Color (Hazen) of Maleic Acid Anhydride0-0.05 E0-3 E
ColorPlus in-lineColor (Hazen) of Maleic Acid Anhydride0-0.05 E0-3 E
DualScat ExTurbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
OilGuardOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces After Separators0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Cooling Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Raw Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces After Separators0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
TurBiScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Sea Water0-01 FNU0-4000 FNU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
DualScat ExTurbidity in Process Water / Waste Water ( Ex-proof)0-2 NTU0-2000 NTU
LabScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
OilGuardOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces After Separators0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Cooling Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Produced Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces After Heat Exchanger0-0.3 FLU0-100 FLU
Oil (HC) Traces After Separators0-0.3 FLU0-100 FLU
Oil (HC) Traces in Condensate0-0.3 FLU0-100 FLU
Oil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Produced Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
TurBiScatTurbidity in Process Water / Waste Water (non Ex-proof)0-4 NTU0-4000 NTU
Turbidity in Sea Water0-01 FNU0-4000 FNU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat PTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
Turbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
DualScat ExTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
LabScatTurbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
TurbiGuardTurbidity For KG Dosing0-1 EBC0-1000 EBC
TurBiScatTurbidity After Plate Filter0-1 EBC0-1000 EBC
Turbidity Before Filling0-1 EBC0-1000 EBC
Turbidity For KG Dosing0-1 EBC0-1000 EBC
Turbidity For Liquid Sugar Filtration Monitoring0-4 NTU0-4000 NTU
Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
Turbidity in Fruit Juice0-4 NTU0-4000 NTU

Our products are used successfully for these applications:

Measuring task
Concentration of Wax in Sunflower Oil
Turbidity in Plant Oil

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
LabScatConcentration of Wax in Sunflower Oil0-2 NTU0-2000 NTU
TurBiScatTurbidity in Plant Oil0-4 NTU0-4000 NTU

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
FireGuardEarly Fire / Smoke Detection in Road Tunnel0-0.05 PLA0-100 PLA
VisGuard ExtractiveDust Concentration in Air0-0.05 PLA0-100 PLA
Visibility in Road Tunnel0-0.05 PLA0-100 PLA
VisGuard In-situDust Concentration in Air0-0.05 PLA0-100 PLA
Visibility in Road Tunnel0-0.05 PLA0-100 PLA
Visibilty & Fire Detection in Road Tunnel0-0.05 PLA0-100 PLA

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat HTTurbidity After Sand Filter0-0.01 FNU0-4000 FNU
Turbidity After Ultra- or Membranfiltration0-0.01 FNU0-4000 FNU
Turbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat PTurbidity After Sand Filter0-0.01 FNU0-4000 FNU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
AquaScat WTMUnknown measuring task
Turbidity After Sand Filter0-0.01 FNU0-4000 FNU
Turbidity After Ultra- or Membranfiltration0-0.01 FNU0-4000 FNU
Turbidity For Flocculant / Lime Dosing0-0.01 FNU0-4000 FNU
Turbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Treated Water0-0.01 FNU0-4000 FNU
ColorPlus bypassColor (GOST Standard) in Water0 - 150 GOST Color
Color (Hazen) of Raw Water0-0.05 E0-3 E
Color (Hazen) of Treated Water0-0.05 E0-3 E
DOC (UV Absorption) And Color (Hazen) in Water0-0.05 E0-3 E
DOC (UV Absorption) in Raw Water0-0.5 E/m0-60 E/m
DOC (UV Absorption) in Treated Water0-0.5 E/m0-30 E/m
Ozone in Air or O20-0.1 g/Nm30-300 g/Nm3
ColorPlus in-lineConcentration of ClO20-0.3 g/l0-15 g/l
DOC (UV Absorption) in Raw Water0-0.5 E/m0-60 E/m
ColorPlus O3 GasOzone Generator Monitoring0-0.1 g/Nm30-300 g/Nm3
Ozone in Air or O20-0.1 g/Nm30-300 g/Nm3
OilGuardOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
Oil (HC) Traces in Raw Water0-0.3 FLU0-100 FLU
OilGuard ExOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
OilGuard Ex MOil (HC) Traces in Process Water / Waste Water0-0.3 FLU0-100 FLU
TurBiScatTurbidity in Raw Water0-0.01 FNU0-4000 FNU
Turbidity in Sea Water0-01 FNU0-4000 FNU

Our products are used successfully for these applications:

Measuring task
Ozone Generator Monitoring

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus O3 GasOzone Generator Monitoring0-0.1 g/Nm30-300 g/Nm3

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
AquaScat PTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
Turbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
DualScat ExTurbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU
LabScatTurbidity in the Spirits, Wine & Softdrinks Laboratory0-2 NTU0-2000 NTU
TurBiScatTurbidity Before Filling0-1 EBC0-1000 EBC
Turbidity For Soya Sauce Filtration Monitoring0-4 NTU0-4000 NTU
Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring0-2 NTU0-2000 NTU

Our products are used successfully for these applications:

Measuring task
Concentration of ClO2

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus in-lineConcentration of ClO20-0.3 g/l0-15 g/l

These products are successfully used in this industry:

ProductMeasuring taskLowest measuring rangeHighest measuring range
ColorPlus in-lineColor (ICUMSA) of Thick-Juice (Sugar)0-0.05 E0-3 E
Color (ICUMSA) of Thin-Juice (Sugar)0-0.05 E0-3 E
TurBiScatTurbidity For Liquid Sugar Filtration Monitoring0-4 NTU0-4000 NTU