Continuous and reliable turbidity measurement helps for optimization, controlling, quality control and monitoring of various processes such as filtration or separation in the fields of potable water treatment, beverages, chemical and pharmazeutical industry.
Our instruments are warrant for low operating cost and offer high quality and added value, sustainability and low energy consumption.
Whether turbidity in potable water or beverages, SIGRIST-PHOTOMETER is your partner of choice.
Products used in turbidity measurement
| Turbidimeters (liquids) |
 | AquaScat HT On-line Turbidimeter (ISO 7027) with free fall flow cell for high turbidities
The AquaScat measures turbidity of potable water according to IEC 27027 in a free-falling water stream. This ... more |
 | AquaScat P On-line Turbidimeter (ISO 7027) for pressurized measurement
The AquaScat measures turbidity of potable water according to IEC 27027 and is specially designed for installations ... more |
 | AquaScat WTM On-line Turbidimeter (ISO 7027) with free fall flow cell with high resolution
The AquaScat measures turbidity of potable water according to IEC 27027 using 90+° scattered light detection in a ... more |
 | DualScat In-Line Turbidimeter (Electronics V.2)
The DualScat monitors turbidity in liquids, using a single light source to detect transmittel light and scattered light ... more |
 | DualScat Ex In-Line Turbidimeter for hazardous areas
The DualScat monitors turbidity in liquids, using a single light source to detect transmittel light and scattered light ... more |
 | LabScat Dual-Angle Lab Turbidimeter
The LabScat monitors turbidity in liquids, using a single light source to detect transmittel light and scattered light ... more |
 | TurBiScat In-Line Turbidimeter
The TurBiScat monitors turbidity in liquids, optional also the (beer)colour in EBC. The combination of Hastelloy and ... more |
Applications in turbidity measurement
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0 ppm | 100 ppm |
| TurBiScat | 0 ppm | 100 ppm |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| LabScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 1 ppm Oil | 100 ppm Oil |
| TurBiScat | 1 ppm Oil | 100 ppm Oil |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.05 mg/m3 PLA | 100 mg/m3 PLA |
| TurBiScat | 0.05 mg/m3 PLA | 100 mg/m3 PLA |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| TurBiScat | 2 NTU | 4000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.5 EBC | 500 EBC |
| TurBiScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat Ex | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| TurBiScat | 0 FNU | 4000 FNU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 2 NTU | 2000 NTU |
| TurBiScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| AquaScat WTM | 0.01 NTU | 4000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0.01 FNU | 4000 FNU |
| TurBiScat | 0.01 FNU | 4000 FNU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| LabScat | 10 ppm SiO2 | 1000 ppm SiO2 |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| LabScat | 0.5 EBC | 500 EBC |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| LabScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| AquaScat P | 2 NTU | 2000 NTU |
| LabScat | 2 NTU | 2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat | 0-2 NTU | 0-2000 NTU |
These products are used:
| Product | Lowest measuring range | Highest measuring range |
| DualScat Ex | 0 | 100 |
Industries in turbidity measurement
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| AquaScat WTM | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| DualScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| DualScat | Turbidity After Lauter Tun (Wort) | 0.5 EBC | 500 EBC |
| Turbidity After Plate Filter | 0.5 EBC | 500 EBC |
| Turbidity After PVPP Filtration | 0.5 EBC | 500 EBC |
| Turbidity After Whirlpool / Centrifuge / Separator | 0.5 EBC | 500 EBC |
| Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For Beer Filtration Monitoring | 0.5 EBC | 500 EBC |
| Turbidity For KG Dosing | 0.5 EBC | 500 EBC |
| Turbidity For PVPP Dosing | 0.5 EBC | 500 EBC |
| LabScat | Turbidity in the Brewery Laboratory | 0.5 EBC | 500 EBC |
| TurBiScat | Turbidity After Lauter Tun (Wort) | 0.5 EBC | 500 EBC |
| Turbidity After Plate Filter | 0.5 EBC | 500 EBC |
| Turbidity After PVPP Filtration | 0.5 EBC | 500 EBC |
| Turbidity After Whirlpool / Centrifuge / Separator | 0.5 EBC | 500 EBC |
| Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For Beer Filtration Monitoring | 0.5 EBC | 500 EBC |
| Turbidity For KG Dosing | 0.5 EBC | 500 EBC |
| Turbidity For PVPP Dosing | 0.5 EBC | 500 EBC |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity For Insuline Filtration | 2 NTU | 2000 NTU |
| Turbidity in Liquified Gas | 2 NTU | 2000 NTU |
| Turbidity in Methacrylic Acid | 2 NTU | 2000 NTU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Silicone Oil | 10 ppm SiO2 | 1000 ppm SiO2 |
| Turbidity in the Chemical- / Pharmaceutical Laboratory | 2 NTU | 2000 NTU |
| TurBiScat | Unknown measuring task | | |
| Turbidity For Insuline Filtration | 2 NTU | 2000 NTU |
| Turbidity in Liquified Gas | 2 NTU | 2000 NTU |
| Turbidity in Methacrylic Acid | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat P | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| DualScat | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| LabScat | Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| TurBiScat | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat WTM | Turbidity in Scrubber Water | 0.01 NTU | 4000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| TurBiScat | Turbidity in instant tea | 0 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| DualScat | Turbidity For Soya Sauce Filtration Monitoring | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity in Herbal Medicines | 2 NTU | 2000 NTU |
| LabScat | Concentration of Wax in Sunflower Oil | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity For Soya Sauce Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity in Fruit Juice | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| AquaScat WTM | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| DualScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| DualScat | ODME For Ballast Water Overboard Discharge | 1 ppm Oil | 100 ppm Oil |
| Oil Mist Detection | 0.05 mg/m3 PLA | 100 mg/m3 PLA |
| TurBiScat | ODME For Ballast Water Overboard Discharge | 1 ppm Oil | 100 ppm Oil |
| Oil Mist Detection | 0.05 mg/m3 PLA | 100 mg/m3 PLA |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Concentration of Water and Solids in Kerosine | 0 ppm | 100 ppm |
| Turbidity in Liquified Gas | 2 NTU | 2000 NTU |
| Turbidity in Methacrylic Acid | 2 NTU | 2000 NTU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity to measure water and solids concentration in kerosene | 0 | 100 |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| TurBiScat | Concentration of Water and Solids in Kerosine | 0 ppm | 100 ppm |
| Turbidity in Liquified Gas | 2 NTU | 2000 NTU |
| Turbidity in Methacrylic Acid | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity of blood plasma | 0-2 NTU | 0-2000 NTU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in the Chemical- / Pharmaceutical Laboratory | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity after filtration of isotonic sodium chloride | 2 NTU | 4000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Scrubber Water | 0.01 NTU | 4000 NTU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
| DualScat Ex | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| LabScat | Turbidity in Process Water / Waste Water | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat P | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| DualScat | Turbidity After Plate Filter | 0.5 EBC | 500 EBC |
| Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For KG Dosing | 0.5 EBC | 500 EBC |
| Turbidity For Liquid Sugar Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| LabScat | Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity After Plate Filter | 0.5 EBC | 500 EBC |
| Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For KG Dosing | 0.5 EBC | 500 EBC |
| Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity in Fruit Juice | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| DualScat | Turbidity in Plant Oil | 2 NTU | 2000 NTU |
| LabScat | Concentration of Wax in Sunflower Oil | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity in Plant Oil | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat HT | Turbidity After Sand Filter | 0.01 FNU | 4000 FNU |
| Turbidity After Ultra- or Membranfiltration | 0.01 FNU | 4000 FNU |
| Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat P | Turbidity After Sand Filter | 0.01 FNU | 4000 FNU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| AquaScat WTM | Unknown measuring task | | |
| Turbidity After Sand Filter | 0.01 FNU | 4000 FNU |
| Turbidity After Ultra- or Membranfiltration | 0.01 FNU | 4000 FNU |
| Turbidity For Flocculant / Lime Dosing | 0.01 FNU | 4000 FNU |
| Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Treated Water | 0.01 FNU | 4000 FNU |
| DualScat | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
| TurBiScat | Turbidity in Raw Water | 0.01 FNU | 4000 FNU |
| Turbidity in Sea Water | 0.01 FNU | 4000 FNU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| AquaScat P | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| DualScat | Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For Soya Sauce Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| DualScat Ex | Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
| LabScat | Turbidity in the Spirits, Wine & Softdrinks Laboratory | 2 NTU | 2000 NTU |
| TurBiScat | Turbidity Before Filling | 0.5 EBC | 500 EBC |
| Turbidity For Soya Sauce Filtration Monitoring | 2 NTU | 2000 NTU |
| Turbidity For Spirits, Wine & Softdrinks Filtration Monitoring | 2 NTU | 2000 NTU |
Our products are used successfully for these applications:
These products are successfully used in this industry:
| Product | Measuring task | Lowest measuring range | Highest measuring range |
| DualScat | Turbidity For Liquid Sugar Filtration Monitoring | 2 NTU | 2000 NTU |
Terms in turbidity measurement
Abbreviation for "European Brewery Convention".
Publishes standard procedures which include a calibration unit based on formazine for ...
more
Abbreviation for "Formazine Nephelometric Unit".
Calibration unit in compliance with standard ISO 7027 for
turbidity measurement using ...
more
The readings shown by turbidimeters are not scaled in the
measured light intensity, but in concentration of a reference suspension. Because ...
more
Kein Glossareintrag für "Kalibrierung" gefunden
Measurement of optical radiation flows (light
intensities) with photometers. In the field of analysis,
distinctions are made between ...
more
Undoubtedly the most important practical field of application
for industrial photometry. All three of the measuring principles employed by ...
more
Impairment of a medium's transparency by the scatter
radiation and absorption caused by optically denser inclusions,
such as ...
more
The turbidity value is the quantitative statement of the
qualitative phenomenon of turbidity. The objective of measuring
turbidity is to ...
more